Standard specification
| Item / Unit |
Model |
HDR-
15AE |
HDR-
22AE |
HDR-
37AE |
HDR-
55AE |
HDR-
75AE |
HDR-
100AE |
| Applicable compressor |
kw |
15 |
22 |
37 |
55 |
75 |
100 |
| Capacity ( Note 1) |
m3/min |
2.4/2.8 |
3.9/4.2 |
6.5/7.0 |
9.2/9.5 |
12.8/13.4 |
16.8/17.6 |
| Max. inlet pressure of compressed air |
MPa |
0.97 |
| Max. inlet temperature of compressed air |
ぃ℃ |
80 |
60 |
| Ambient temperature |
ぃ℃ |
5~40 |
| P.D.P |
℃ |
10 under pressure |
| Rated output of refrigerator |
kw |
0.5 |
1.1 |
1.1 |
1.85 |
3.0 |
3.75 |
| Cooling method of condenser |
- |
Air cooled |
| Refrigerant control device |
- |
Capillary tube |
| Capacity control device |
- |
Hot gas bypass valve |
| Refrigerant used |
- |
HFC-R407C |
| Finish color |
- |
lvory (Munsell No. 5Y8.5/1) |
| Pipe conection |
B |
1 |
1 |
1 1/2 |
1 1/2 |
2(Flange) |
2(Flange) |
| Dimensions (WxDxH) |
mm |
303x678x681 |
303x753x681 |
303x1,033x751 |
303x1,083x981 |
431x1,183x1,124 |
491x1,323x1,164 |
| Weight |
kg |
54 |
58 |
94 |
127 |
205 |
245 |
| Accessories |
- |
Auto drain trap / Drain valve |
|
Hitachi Filter

|
Standard specification
| Item |
Model |
HDF-
7.5B |
HDF-
11
B |
HDF-
15B |
HDF-
22B |
HDF-
37B |
HDF-
55B |
HDF-
75B |
HDF-
100B |
HDF-
240B |
HDF-
400B |
HDF-
480A |
AIR
Conditon |
Applicable compressor |
kw |
1.2 |
1.8 |
2.4 |
3.9 |
6.6 |
10.6 |
13.8 |
20 |
24.4 |
40 |
48.8 |
| Capacity ( Note 1) |
℃ |
30 |
| Inlet air pressure |
MPa |
0.69 |
Use
Conditons |
Usable fluid |
_ |
Compressed air |
| Max. pressure |
MPa |
0.97 |
| Inlet air temperature
range |
℃ |
5~60 |
| Ambient temperature range |
℃ |
2~60 |
| Filtration rating |
µm |
1 (Note 1) |
approx.3 |
| Filtration efficiency |
% |
99.999 |
Pressure
drop |
Initial |
MPa |
0.005 or lower |
| Teminal (to replace element) |
MPa |
0.07 |
| Connecting pipe diameter |
B (A) |
Rc 1/2 |
Rc 3/4 |
Rc 3/4 |
Rc 1 |
Rc1 1/2 |
Rc1 1/2 |
Rc 2 |
Rc 2 |
2 1/2
(Flange) |
3
(Flange) |
4
(Flange) |
Dimensions
(diameter x length) |
mm |
90x231 |
115x287 |
115x455 |
160x509 |
170x591 |
170x699 |
173x792 |
173x949 |
420x1,690 |
500x1,521 |
500x1,752 |
| Weight |
kg |
1 |
1.5 |
2 |
3 |
3.3 |
3.7 |
4.3 |
6 |
80 |
120 |
135 |
Note: 1.corresponds to the 2nd of " compressed air grades " in ISO8573-1, The inlet oil content is 3wtppm. |
Multi Unit Controller (STEPROLLER Ⅱ ) |
 |
Standard specification
| Item |
Model |
SR-14 |
SR-18 |
SR-24 |
SR-28 |
| Power source |
AC100V |
AC200V |
| Controllable number of units |
4 |
8 |
4 |
8 |
| Input |
Discharge pressure |
0~0.98MPa (digital display) |
| Control |
Operation answer / failure |
| External |
Rotation, initial air charging, start / stop |
| Output |
Control |
Operation, stop, load instruction |
| External |
Power off, failure, pressure drop |
| Controllable width of discharge |
Min.± 0.01MPa * |
| Dimensions (WxDxH) |
480x180x600 (mm) |
| Weight |
30kg |
|

|